ATO-750 Series OTDR

(Optical Time Domain Reflectometer)

Acuteq OTDR ATO-750 Introduction

Features:

      1.  Event Map (Smart Link Analyzer)
      2.  5.6-inch HD touch screen
      3.  User-Friendly
      4.  Ultra-High Capacity BatterySupport
      5.  Multi-language
      6.  Multi-functions

Description:

       ATO-750 OTDR is used in the installation and maintenance of fiber optic cables. Acuteq OTDR has the advantage of high precision test capabilities, fast response time and easy to learn to operate. The ATO-750 Series offers accurate and fast results and creates a report automatically.

Structure:

 

 

 

 

 

 

 

General Specification

Display

5.6-inch TFT-LCD (touch screen )

Battery

7.4V/2500mAh X 2 lithium battery

Continuously test: 8 hours (backlight off),③ Charging time: 3 hours

Data Storage

100,000 groups of curves

Interface

USB A Type×1, Micro-USB×1)

Working Temp

-10℃~+50℃

Storage Temp

-20℃~+70℃

Humidity

≤95% (non-condensation)

Accessories

Main unit, 12V power adapter, Lithium battery, FC adapter, USB cord, User guide, carrying case, wrist belt

Dimension

8.5× 6×2.7 inches/ 1.25 pounds (battery included)

215×155×68 mm/ 1.1kg (battery included)

Test parameter

Pulse Width

3ns, 5ns, 10ns, 20ns, 50ns, 100ns, 200ns, 500ns, 1μs, 2μs, 5μs, 10μs, 20μs

Testing Distance

500m,1km, 2km, 5km, 10km, 20km, 40km, 80km, 120km, 200km, 240km

Sampling Resolution

Minimum 5cm

Sampling Point

Maximum 256,000 points

Linearity

≤0.05dB/dB

scale Indication

X axis: 4~70m/div, Y axis: 0.09~5dB/div

Loss Threshold

0.01dB

Loss Resolution

0.001dB

Distance Resolution

0.01m

Distance Accuracy

±(1m+measuring distance×3×10-5+sampling resolution) (excluding IOR uncertainty)

Refraction Setting

1.2000~1.5999, 0.0001 step

VFL Module (Optional)   

Wavelength

650nm

Power

10mw, CLASS III B

Range

12km

Connector

FC/UPC

Launching Mode

CW/2Hz

OPM Module (Optional)

Wavelength Range

800~1700nm

Calibrated Wavelength

850/1300/1310/1490/1550/1625/1650nm

Test Range

-60~+5dBm

Resolution

0.01dB

Accuracy

±0.35dB±1nW

Modulation Identification

270/1k/2k Hz,Pi≥-40dBm

Connector

FC/UPC

LS Module (Optional)

Wavelength Range

1310/1550/1625/,850/1300

Output

-5dBm±2dB

Output mode

CW/270/1k/2k Hz

Connector

FC/UPC

Other Modules (Optional)

GPS/GNSS

Customized

WIFI/Bluetooth

Customized

IoT module

Customized

  

Packing Info

Dimension (L*W*H)

13.5×10×6.5 inches

340×255×160mm

Weight

6.8 Pounds

(Including Battery)

3.1KG

(Including Battery)

Model Number

Model

Wavelength

(nm)

Dynamic Range(dB)①

Event/Attenuation Dead Zonem

ATO-750-D28

1310/1550

28/26

0.8/4

ATO-750-D32

1310/1550

32/30

0.8/4

ATO-750-D35

1310/1550

35/33

0.8/4

ATO-750-D37

1310/1550

37/35

0.8/4

ATO-750-D40

1310/1550

40/38

0.8/4

ATO-750-D42

1310/1550

42/40

0.8/4

ATO-750-TS26

1625

26

0.8/4

ATO-750-TS32

1625

32

0.8/4

ATO-750-TCS26

1650

26

0.8/4

ATO-750-TCS32

1650

32

0.8/4

ATO-750-T35

1310/1550/1625

35/33/32

0.8/4

ATO-750-TC35

1310/1550/1650

35/33/32

0.8/4

ATO-750-M24

850/1300

20/24

1.2/5

ATO-750-MD28

1310/1550

850/1300

28/26

28/30

SM:0.8/4

MM:1.2/5

ATO-750-MD35

1310/1550

850/1300

35/32

28/30

SM:0.8/4

MM:1.2/5

Notes:

①Dynamic range is measured with maximum pulse width, averaging time is 3 minutes, SNR=1; The level difference between the RMS noise level and the level where near end back-scattering occurs.

②Event dead zone is measured with the pulse width of 3ns; attenuation dead zone is measured with the pulse width of 5ns.

 

Detailed Software Features

 

User-Friendly Menu

The simplified menu helps customers understand the test results easily.

 

Data Manager(PC)

Within a few steps, Customers can print out detailed result files by using the Use Data Manager(PC).

Detailed Report

Brief but nor simplified report and support multi-result printing.

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.